Fujitsu Laboratories Ltd. have announced the development of the world’s first biometric authentication technology that combines data on palm vein patterns with fingerprint data from three fingers. By employing both palm vein pattern and fingerprint data, the technology enables the rapid identification of a given individual out of data from a million people, processing the match within two seconds.

This technology makes it possible to construct biometric authentication systems that do not require ID cards and that can be tailor-made to fit different sized groups, from small-scale room access control to large-scale social platform systems. Moreover, the technology can be easily deployed by simply adding palm vein authentication to the fingerprint authentication systems that are already in widespread use.

Figure 1: Personal authentication combining palm vein patterns with three fingerprints

Biometric authentication technology is becoming increasingly ubiquitous as a means to prevent corporate data breaches and identity fraud at financial institutions. This includes palm vein authentication based on a technology pioneered by Fujitsu Laboratories, now widely employed around the world for its highly precise authentication in applications ranging from ID confirmation for ATM users at financial institutions, to corporate PC access management and room access control systems. In addition, rapid fingerprint authentication processing is becoming popular as an easy and reliable personal log-in authentication method built into PCs and mobile phones.

The convenience offered by simply using one’s body for authentication—biometrics eliminates the need to carry IC cards—is expected to accelerate the spread of biometrics even further. As the key to realize greater acceptance, the focus has turned to technologies that can recognize with superior speed and precision a given individual out of a million or hundred million people in applications for large corporations and governments.

Figure 2: Authentication service using only biometric data
To determine whether specific biometric data of a given individual recorded in an IC card is a match or not (one-to-one matching), such as is the case for authentication systems used in financial institutions, current authentication methods using just one type of biometric data are sufficient. However, when attempting to distinguish and identify a given person from a group of many people (one-to-many matching), precision becomes problematic if the pool of people is as large as a million or ten million people. This results in cases in which it is impossible to clearly distinguish among potential matches using just one type of biometric data. For one-to-many matching, because authentication requires sifting through all records registered in a system, the level of precision required to authenticate one person out of a pool of one million is a million times the level of precision required for one-to-one matching.

One solution proposed for addressing this problem is to build a robust authentication system that combines multiple biometric authentication methods. Separately capturing the biometric data needed for each method, however, diminishes the convenience of this approach. For example, if palm vein authentication were combined with iris pattern authentication, both the palm and iris would each need to be separately scanned, compromising simplicity. This necessitated a technology that could easily combine more than one type of biometric data.

Moreover, in order to authenticate one person out of a million, because processing entails sifting through all one million records, authentication processing could take over twenty minutes using conventional technologies. Accordingly, also needed was technology that would dramatically reduce required processing time.

Fujitsu Laboratories has developed a system that can identify a given person out of a pool of a million people, delivering one-to-one million matching. This was accomplished by combining fingerprint authentication, already in wide use and easily performed at high speed, with palm vein authentication, which has superior accuracy and is extraordinarily difficult to falsify, making it highly secure against fraud. The system developed with this technology uses palm vein and fingerprint data from three fingers. Capturing both finger and palm vein data in a single scan, the identity of a given person from a pool of a million can be authenticated within two seconds through parallel processing on multiple servers.

Features of the newly developed technology are as follows:

  1. Simultaneous and accurate capture of palm vein and three-fingerprints data. Despite the different methods required to capture palm vein patterns and fingerprints from three fingers, Fujitsu Laboratories developed technology that is able to accurately capture both sets of data through a one-time scan of a person’s hand. Know-how accumulated in developing high-speed image capturing of palm vein patterns is used to capture data on palm vein patterns and fingerprints enabling smooth and accurate authentication in a single motion.
  2. Instantly narrows down potential matches in authentication process. Fujitsu Laboratories developed technology that instantly narrows down potential matches to speed the authentication process, even from a pool of a million people. Using data extracted from four different groups of biometric feature data—comprised of the palm vein pattern plus three fingerprints—this technology enables potential matches to be instantly and accurately narrowed down to pinpoint the identity being authenticated.
  3. Accurate identification by combining palm vein pattern with multiple fingerprints. For superior precision, an individual is identified by his or her palm vein pattern and three fingerprints. The technology accurately authenticates an individual’s identity by processing the identification from among a narrowed-down pool of potential matches, and combining the results from the palm vein pattern with three fingerprints.
  4. Leverages the power of parallel processing. Fujitsu Laboratories developed technology that uses parallel processing for authentication. Because it is possible to increase or decrease the number of servers used in authentication processing depending on the size of the pool of potential matches, it is well-suited to cloud-based environments.
Figure 3: Overview of the newly developed authentication system
This technology enables authentication of a certain individual’s identity from a group of one million. For example, because an individual’s identity can be authenticated with biometric data alone without the individual having to carry an ID card, it is anticipated that this technology could be employed in a wide variety of situations that require both security and ease of use. Authentication among large groups of people can be performed by simply deploying additional servers. As such, countries where residency registration systems are underdeveloped can use this technology to provide an ID for each individual, creating a basic system built upon a foundation of social information.

This technology is also able to use, without alteration, the fingerprint imaging data from general-purpose fingerprint sensors already used in applications such as border control and residency identification. Accordingly, by simply adding palm vein pattern authentication to widely used fingerprint authentication systems, this new technology can be easily deployed.

Figure 4: Application scenarios for large-scale biometric authentication services
 
Through further refinements to increase speed and precision, Fujitsu Laboratories plans to make it feasible to authenticate groups on the scale of 10 million people within fiscal 2011, and will also consider applications in a variety of scenarios.

5 comments

  1. Fujitsu marketing keeps depicting their vein scanner being used with the hand held in mid air. Yet a training video for an OEM scanner — which I believe incorporates the Fujitsu sensor — stresses how important it is to keep the hand in exactly the right position each time. See http://www.youtube.com/user/M2SYS?feature=mhum#p/a/u/0/lOdhbde9-Zw.

    I conclude that the system is mighty sensitive to angle (pitch, roll and yaw) and distance, and that it is not advisable to hold your hand vaguely in the vicinity of the scanner as so often suggested. And another thing: the superior hygeine claims made elsewhere for palm vein technology are fanciful if in practice users actually need to fit their hands snugly into finger guides.

  2. عندي فكرة ابسط من ذلك وعند تنفيدها ستكون اكثر فاعلية من هذه الفكرة وسيتم بواسطتها تغطية جميع الليات الموثوقية باستخدام اداة واحدة الشركة التي تكون جاهزة لدفع ثمن الفكرة تتصل بي

Leave a Reply

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Discover more from Silicon Trust

Subscribe now to keep reading and get access to the full archive.

Continue reading